LT1025
APPLICATIO S I FOR ATIO
3. Calibrate output by adding in a true offset term which
does not affect gain (by summing, etc.). Calibration may
be done at any temperature either by immersing the
thermocouple in a calibrated bath or by substituting a
precision input voltage. The method which tends to
minimize worst-case error over the whole TL to TH range
is to calibrate at 1/6 or 5/6 of span. This may be modified
if best accuracy is desired at one particular point.
Breakpoint correction for nonlinearity is more compli-
cated than a simple offset, but a single breakpoint com-
bined with offset will reduce errors typically by 4:1 over a
simple offset technique.
TYPICAL APPLICATIO S
Eliminating Amplifier Feedback Resistors
(Output Goes Negative with Increasing Temperature)
15V
VIN
3k
+–
C2
1µF
TYPE K
C1
0.1µF
15V
27
LTKA0x††
3+
4
–15V
LT1025
K
GND
RVO
300k
–15V
6
VOUT
–10mV/°C
†† OR EQUIVALENT. SEE “AMPLIFIER CONSIDERATIONS”
Type K Thermometer with Grounded Thermocouple
R3
R2
255k
100
1%
R1
1k
1%
R5
10k
C2
1µF
TYPE K
R6
9.1k 0.1µF
V+
LTKA0x††
+
V
V+
VIN VO
LT1025
GND R
VOUT
10mV/°C
R4*
470k
V
–15V
*R4 VIF OUTPUT MUST SINK CURRENT, R4
30µA
MUST BE DECREASED APPROPRIATELY. R4 IS NOT
REQUIRED (OPEN) FOR LT1025 TEMPERATURES 0°C
WHEN SOURCING CURRENT ONLY
†† OR EQUIVALENT. SEE “AMPLIFIER CONSIDERATIONS”