4.3. Test method :
4.3.1. Insertion loss for POTS :
4.3.1.1. Description :
Insertion loss /Attenuation mentioned herein is defined as below :
IL = 20 log 10 Vo/Vi dB
Vo = the voltage value measured across the Line side shown in fig .2
Vi = the voltage value measured across the Phone side fig .1
4.3.1.2. Apparatus :
a . Function generator or equivalent
b . Readout oscilloscope or equivalent.
c . Complex load ZL = Zcomplex(1) or Zcomplex(2) or Zcomplex(3) or 600ohms
d . ZHP-c = 2350pf+26.5µH + 2200pf
4.3.1.3. Test procedure :
a . Set the measurement Frequency of interest
b . Connecting the source to the Phone side of splitter with the complex load ZL
across the Line side.
c . Measure the voltage value and calculate the Insertion loss expressed in decibel
from the equation Insertion loss = 20 log10 Vo / Vi dB
d . Change another frequency of interested the repeat step a~d.
4.3.1.4. Insertion loss test set up measurement :