DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

TDAT021G2 데이터 시트보기 (PDF) - Agere -> LSI Corporation

부품명
상세내역
제조사
TDAT021G2
Agere
Agere -> LSI Corporation 
TDAT021G2 Datasheet PDF : 310 Pages
First Prev 11 12 13 14 15 16 17 18 19 20 Next Last
TDAT042G5 Device Advisory
for Version 1 and 1A of the Device
Advisory
May 2001
Data Engine (DE) (continued)
DE10. Excessive HDLC Flag Characters
The following three issues refer to HDLC flag character (0x7E) problems in the data engine:
I An excessive number of HDLC flag characters (0x7Es) may be inserted between packets on the transmit side if
the UTOPIA low watermark value is set above 2. This will have the effect of reducing the bandwidth of the device.
I The data engine operates on 32-bit boundaries. Egress packets that are not multiples of four will be filled with
0x7Es.
I Egress packets consisting of all 0x7Es as data will be corrupted.
Workaround
Set the UTOPIA egress low watermark value in the UTOPIA egress provisioning registers (0x0212, 0x0216,
0x021A, 0x021E) to either 1 or 2 to prevent excessive 0x7Es from being inserted between packets.
Corrective Action
This condition will be addressed in future versions of the device.
UTOPIA (UT)
UT1. Polling in Multidevice MPHY Mode
When the TDAT042G5 is polled and responds, the data bus becomes enabled. In a multidevice MPHY configura-
tion, if the data bus is active from a different PHY device, response to a poll from the device will corrupt a data
transfer already in progress. TDAT042G5 MPHY always functions without data corruption in a single-device
(slave), multiple-channel configuration (point-to-point).
Workaround
No workaround is available for this condition.
Corrective Action
This condition will be addressed in future versions of the device.
12
Agere Systems Inc.

Share Link: 

datasheetq.com  [ Privacy Policy ]Request Datasheet ] [ Contact Us ]