TB2932HQ
Multiple faults
The self diagnosis shows as below tables when there are multi fault connection for the audio
outputs.
At Turning ON:
S.GND (out+)
S.GND (out−)
S.VCC
Out to Out.S
Open L
S.GND (out+)
S.GND
S.GND (out−)
S.GND
S.GND
S.VCC
SVCC+S.Load
S.Load
S.VCC
Out to Out. S
S.GND
S.GND
S.VCC
S.Load
Open L
S.GND + No open
S.GND + No open
S.VCC + S.Load +
open or No open
S.Load + No open
Open
At Permanent:
S.GND (out+)
S.GND (out−)
S.VCC
Out to Out.S
Open L
S.GND (out+)
S.GND
S.GND (out−)
S.GND
S.GND
S.VCC
S.LOAD or
S.VCC
(Note 10)
S.GND or S.VCC
(Note 10)
Out to Out. S
S.GND
S.GND
S.VCC
S.VCC
S.Load + S.GND
Open L
S.GND
(Note 9)
S.GND
(Note 9)
S.VCC
(Note 9)
N/A
Normal
Note 9: If the DC offset detection mode is ON, the information which the DC offset is appeared is added.
Note10: The chance which they can read this exact information is only one time although in case of other
diagnosis, the more times sending read command, the higher the confidence of the result.
For example,
a) ch1+ is connected to GND
b) ch1− is connected to VCC
c) They can read or get the “Short to GND” information when the uP send the Read command.
d) Next, however, they can not get the “Short to GND” or “Short to VCC” information when the uP
send the Read command again.
Note 11: Please arrange to read all self-diagnosis functions twice or more and apply judgment in order to
avoid false triggering.
Explanation of I2C bus commands
Below the “ADDRESS BYTE”, presently the address byte is fixed at 216 dec = D8hex = 101100xbin.
- Address Selection is D8hexa:
A7
Address bit
1
A6
Address bit
1
A5
Address bit
0
A4
Address bit
1
A3
Address bit
1
A2
Address bit
0
A1
Address bit
0
A0 (R/W)
Read/Write bit
X
X: 0 = Write instruction to device; 1 = Read instruction to device
15