TB2932HQ
- If R/W = 1, the Power Amplifier Sends Four Diagnostics Bytes, DB1, DB2, DB3 and DB4:
DB1 Diagnostic Byte:
Bit
D7 Thermal warning active (D7 = 1)
D6 Diag not actived or not terminated (D6 = 0)
Diag terminated (D6 = 1)
D5 Channel 1 current detection
Output peak current < 250 mA (IB2 − D7 = 0) − open load (D5 = 1)
Output peak current < 100 mA (IB2 − D7 = 1) − open load (D5 = 1)
Output peak current > 500 mA (IB2 − D7 = 0) − normal load (D5 = 0)
Output peak current > 300 mA (IB2 − D7 = 1) − normal load (D5 = 0)
D4 Channel 1
Turn-on diagnostic (D4 = 0)
Permanent diagnostic (D4 = 1)
D3 Channel 1
Normal load (D3 = 0)
Short load (D3 = 1)
D2 Channel 1
Turn-on diag: No open load (D2 = 0)
Open load detected (D2 = 1)
Offset diag: No output offset (D2 = 0)
Output offset detected (D2 = 1)
D1 Channel 1
No short to VCC (D1 = 0)
Short to VCC (D1 = 1)
D0 Channel 1
No short to GND (D0 = 0)
Short to GND (D0 = 1)
17