Nexperia
74LVC1G04
Single inverter
11 Dynamic characteristics
Table 8. Dynamic characteristics
Voltages are referenced to GND (ground = 0 V). For test circuit see Figure 9.
Symbol Parameter
Conditions
-40 °C to +85 °C
Min Typ[1] Max
tpd
propagation delay A to Y; see Figure 8
[2]
VCC = 1.65 V to 1.95 V
1.0
3.0
7.5
VCC = 2.3 V to 2.7 V
0.5
2.0
5.0
VCC = 2.7 V
0.5
2.3
5.2
VCC = 3.0 V to 3.6 V
0.5
2.0
4.2
VCC = 4.5 V to 5.5 V
0.5
1.6
3.7
CPD
power dissipation VI = GND to VCC; VCC = 3.3 V [3] -
14
-
capacitance
[1] Typical values are measured at Tamb = 25 °C and VCC = 1.8 V, 2.5 V, 2.7 V, 3.3 V and 5.0 V respectively.
[2] tpd is the same as tPLH and tPHL.
[3] CPD is used to determine the dynamic power dissipation (PD in μW).
PD = CPD x VCC2 x fi x N + ∑(CL x VCC2 x fo) where:
fi = input frequency in MHz;
fo = output frequency in MHz;
CL = output load capacitance in pF;
VCC = supply voltage in V;
N = number of inputs switching;
∑(CL x VCC2 x fo) = sum of outputs.
-40 °C to +125 °C Unit
Min
Max
1.0
9.5
ns
0.5
6.5
ns
0.5
7.0
ns
0.5
5.5
ns
0.5
5.0
ns
-
-
pF
11.1 Waveform and test circuit
VI
A input
VM
GND
VOH
tPHL
Y output
VM
VOL
Measurement points are given in Table 9.
VOL and VOH are typical output voltage levels that occur with the output load.
Figure 8. The input A to output Y propagation delays
t PLH
mna640
74LVC1G04
Product data sheet
All information provided in this document is subject to legal disclaimers.
Rev. 15 — 8 June 2018
© Nexperia B.V. 2018. All rights reserved.
8 / 21