Table 34. STAGEx_CONNECTION [6:0] Register Description (x = 0 to 11)
Default
Data Bit Value Type
Name
Description
[1:0]
X
R/W
CIN0_CONNECTION_SETUP
CIN0 connection setup
00 = CIN0 not connected to CDC inputs
01 = CIN0 connected to CDC negative input
10 = CIN0 connected to CDC positive input
11 = CIN0 connected to BIAS (connect unused CINx inputs)
[3:2]
X
R/W
CIN1_CONNECTION_SETUP
CIN1 connection setup
00 = CIN1 not connected to CDC inputs
01 = CIN1 connected to CDC negative input
10 = CIN1 connected to CDC positive input
11 = CIN1 connected to BIAS (connect unused CINx inputs)
[5:4]
X
R/W
CIN2_CONNECTION_SETUP
CIN2 connection setup
00 = CIN2 not connected to CDC inputs
01 = CIN2 connected to CDC negative input
10 = CIN2 connected to CDC positive input
11 = CIN2 connected to BIAS (connect unused CINx inputs)
[7:6]
X
R/W
CIN3_CONNECTION_SETUP
CIN3 connection setup
00 = CIN3 not connected to CDC inputs
01 = CIN3 connected to CDC negative input
10 = CIN3 connected to CDC positive input
11 = CIN3 connected to BIAS (connect unused CINx inputs)
[9:8]
X
R/W
CIN4_CONNECTION_SETUP
CIN4 connection setup
00 = CIN4 not connected to CDC inputs
01 = CIN4 connected to CDC negative input
10 = CIN4 connected to CDC positive input
11 = CIN4 connected to BIAS (connect unused CINx inputs)
[11:10]
X
R/W
CIN5_CONNECTION_SETUP
CIN5 connection setup
00 = CIN5 not connected to CDC inputs
01 = CIN5 connected to CDC negative input
10 = CIN5 connected to CDC positive input
11 = CIN5 connected to BIAS (connect unused CINx inputs)
[13:12]
X
R/W
CIN6_CONNECTION_SETUP
CIN6 connection setup
00 = CIN6 not connected to CDC inputs
01 = CIN6 connected to CDC negative input
10 = CIN6 connected to CDC positive input
11 = CIN6 connected to BIAS (connect unused CINx inputs)
[15:14]
X
Unused