TABLE II. Electrical test requirements.
Test requirements
Interim electrical
parameters (see 4.2)
Final electrical
parameters (see 4.2)
Group A test
requirements (see 4.4)
Group C end-point electrical
parameters (see 4.4)
Group D end-point electrical
parameters (see 4.4)
Group E end-point electrical
parameters (see 4.4)
Subgroups
(in accordance with
MIL-STD-883,
method 5005, table I)
Device
class M
1
Subgroups
(in accordance with
MIL-PRF-38535, table III)
Device
class Q
1
Device
class V
1
1,2,3,9,10,11 1/
1,2,3,9,10,11
1
1
----
1,2,3,9, 1/
10,11
1,2,3,9,
10,11
1
1
----
1,2,3,9, 1/
10,11
1,2,3,9,
10,11
1,2,3,9,
10,11
1,2,3,9,
10,11
----
1/ PDA applies to subgroup 1.
4.4.3 Group D inspection. The group D inspection end-point electrical parameters shall be as specified in table II herein.
4.4.4 Group E inspection. Group E inspection is required only for parts intended to be marked as radiation hardness
assured (see 3.5 herein).
a. End-point electrical parameters shall be as specified in table II herein.
b. For device classes Q and V, the devices or test vehicle shall be subjected to radiation hardness assured tests as
specified in MIL-PRF-38535 for the RHA level being tested. For device class M, the devices shall be subjected to
radiation hardness assured tests as specified in MIL-PRF-38535, appendix A for the RHA level being tested. All
device classes must meet the postirradiation end-point electrical parameter limits as defined in table I at
TA = +25°C ±5°C, after exposure, to the subgroups specified in table II herein.
c. When specified in the purchase order or contract, a copy of the RHA delta limits shall be supplied.
5. PACKAGING
5.1 Packaging requirements. The requirements for packaging shall be in accordance with MIL-PRF-38535 for device
classes Q and V or MIL-PRF-38535, appendix A for device class M.
6. NOTES
6.1 Intended use. Microcircuits conforming to this drawing are intended for use for Government microcircuit applications
(original equipment), design applications, and logistics purposes.
6.1.1 Replaceability. Microcircuits covered by this drawing will replace the same generic device covered by a contractor
prepared specification or drawing.
6.1.2 Substitutability. Device class Q devices will replace device class M devices.
6.2 Configuration control of SMD's. All proposed changes to existing SMD's will be coordinated with the users of record for
the individual documents. This coordination will be accomplished using DD Form 1692, Engineering Change Proposal.
STANDARD
MICROCIRCUIT DRAWING
DEFENSE SUPPLY CENTER COLUMBUS
COLUMBUS, OHIO 43216-5000
DSCC FORM 2234
APR 97
SIZE
A
REVISION LEVEL
A
5962-94686
SHEET
10