ADG621/ADG622/ADG623
TYPICAL PERFORMANCE CHARACTERISTICS
8
TA = 25°C
7
VDD, VSS = ±2.5V
6
VDD, VSS = ±3V
5
VDD, VSS = ±3.3V
4
3 VDD, VSS = ±4.5V
2
VDD, VSS = ±5V
1
0
–5 –4 –3 –2 –1 0 1 2 3 4 5
VD, VS (V)
Figure 5. On Resistance vs. VD, VS (Dual Supply)
20
VDD = 2.7V
TA = 25°C
VSS = 0V
16
VDD = 3V
12
VDD = 3.3V
8
VDD = 5V
4
VDD = 4.5V
0
0
1
2
3
4
5
VD, VS (V)
Figure 6. On Resistance vs. VD, VS (Single Supply)
10
VDD = 5V
9
VSS = 0V
8
TA = +85°C
7
TA = +25°C
6
TA = –40°C
5
4
3
2
1
0
0
1
2
3
4
5
VD, VS (V)
Figure 8. On Resistance vs. VD, VS for Different Temperature
(Single Supply)
0.5
0.4
0.3
0.2
IS (OFF)
0.1
0
–0.1
–0.2
ID, IS (ON)
ID (OFF)
–0.3
–0.4
VDD = +5V
VSS = 0V
VD = ±4.5V
VS = ±4.5V
–0.5
0
10 20 30 40 50 60 70 80
TEMPERATURE (°C)
Figure 9. Leakage Current vs. Temperature (Dual Supply)
6
VDD = +5V
VSS = –5V
5
TA = +85°C
4
TA = +25°C
3
TA = –40°C
2
1
0
–5 –4 –3 –2 –1 0 1 2 3 4 5
VD, VS (V)
Figure 7. On Resistance vs. VD, VS for Different Temperatures
(Dual Supply)
0.5
0.4
0.3
0.2
IS (OFF)
0.1
0
–0.1
ID, IS (ON)
–0.2
ID (OFF)
–0.3 VDD = 5V
VSS = 0V
–0.4 VD = 4.5V/1V
VS = 1V/4.5V
–0.5
0
10
20
30 40
50
60
70
80
TEMPERATURE (°C)
Figure 10. Leakage Current vs. Temperature (Single Supply)
Rev. B | Page 8 of 12