AIC1781
Power ON
LED Flash 3 Times
If
VBT in Normal
Range
Yes
If
VNTC<0.72 VCC
No
Yes
If VNTC>0.29VCC
Yes
If
Discharge
Finished
If
Yes
Discharge
Enabled
Yes
No
LED's Display Fast Charge, ICON OFF
Safety Timer Counts
No
No
No
LED's Display Abnormal,
ICON ON,
Safety Timer Reset
Yes
If
SEL3>VCC-0.3V
or VCC/2-0.4V>SEL3
No
>1.4V
∆
T/
∆
t Disabled
If
SEL3>VCC-0.3V
or VCC/2-0.4V>SEL3
>1.4V
LED's Display,
Yes
Abnormal,
ICON ON,
Safety Timer Reset
No
Battery Replacement
Yes
No
∆
T/
∆
t Detector,
-
∆
V Detector,
Peak timer are all
Disabled
No
If
Initial Timer
Finished
No
Yes
If
Peak Timer Period
Yes
has Finished
No
If
0.25% Decline of VBT
Yes
is Detected
No
If
∆
T/
∆
=
t
has Reached
Yes
No
If
Safety Timer Period
Yes
has Finished
LED's Display
Battery Fulll,
Fast Charge
Finished,
Trickle charge
Starts
Battery Replacement Yes
No
Fig. 2 Function Flow Chart of AIC1781