CLP270M
The figure 9 shows two different curves :
s The lower one indicates the maximum guaranted working limits of the CLP270M.
Table 1: First level lightning surge.
Surge
1
2
3
4
5
Minimum
peak voltage
(volts)
Minimum
peak current
per conductor
(Amps)
Maximum rise
/ Minimum
decay time for
voltage and
current
(µs)
Repetitions,
each polarity
+/- 600
100
10/1000
25
+/- 1000
100
10/360
25
+/- 1000
100
10/1000
25
+/- 2500
500
2/10
10
+/- 1000
25
10/360
5
Test
connections
per
table 4.1
A
A
A
B
B
Table 2: Second level lightning surge.
Surge
1
Minimum
peak voltage
(volts)
Minimum
peak current
per conductor
(Amps)
Maximum rise
/ Minimum
decay time for
voltage and
current
(µs)
Repetitions,
each polarity
+/- 5000
500
2/10
1
Test
connections
per
table 4.1
B
s The upper curve shows the limit above which the CLP270M is completely destructed . In this case, the
Fail Diagnostic pin is on.
3. CLP270M TEST RESULTS ACCORDING TO BELLCORE 1089 REQUIREMENTS.
8/24