IC62LV12816L
IC62LV12816LL
AC TEST CONDITIONS
Parameter
Input Pulse Level
Input Rise and .all Times
Input and Output Timing
and Reference Level
Output Load
Unit
0.4V to 2.2V
5 ns
1.3V
See .igures 1 and 2
AC TEST LOADS
OUTPUT
1 TTL
100 pF
Including
jig and
scope
.igure 1
OUTPUT
1 TTL
5 pF
Including
jig and
scope
.igure 2
IC62LV12816L POWER SUPPLY CHARACTERISTICS(1) (Over Operating Range)
Symbol Parameter
ICC
Vcc Dynamic Operating
Supply Current
ISB TTL Standby Current
(TTL Inputs)
OR
Test Conditions
VCC = Max.,
IOUT = 0 mA, f = fMAX
VCC = Max.,
VIN = VIH or VIL,
CE £ VIH, f = 0
-55
-70
-100
Min. Max. Min. Max. Min. Max. Unit
Com. 40
Ind. 45
30
35
20
mA
25
Com. 0.5
Ind. 1.0
0.5
1.0
0.5 mA
1.0
ULB Control
VCC = Max., VIN = VIH or VIL
CE = VIL, f = 0, UB = VIH, LB = VIH
ISB
CMOS Standby
VCC = Max.,
Com. 35
Current (CMOS Inputs) CE ³ VCC 0.2V,
Ind. 50
VIN ³ VCC 0.2V, or
VIN £ 0.2V, f = 0
OR
35
50
35
µA
50
ULB Control
VCC = Max., CE = VIL
VIN £ 0.2V, f = 0, UB / LB = VCC 0.2V
Note:
1. At f = fMAX, address and data inputs are cycling at the maximum frequency, f = 0 means no input lines change.
4
Integrated Circuit Solution Inc.
LPSR011-0B 06/06/2001