KA3842B/KA3843B/KA3844B/KA3845B
Figure 2. Under Voltage Lockout
During Under-Voltage Lock-Out, the output driver is biased to a high impedance state. Pin 6 should be shunted to ground
with a bleeder resistor to prevent activating the power switch with output leakage current.
Figure 3. Error Amp Configuration
Figure 4. Current Sense Circuit
Peak current (IS) is determined by the formula:
IS(MAX)=
1----.--0---V---
RS
A small RC filter may be required to suppress switch transients.