MC74LVX257
DC CHARACTERISTICS (Voltages Referenced to GND)
VCC
TA = 25°C
−40°C ≤ TA ≤ 85°C
Symbol
Parameter
Condition
(V)
Min
Typ
Max
Min
Max Unit
VIH Minimum High−Level
Input Voltage
2.0 0.75 VCC
3.0
0.7 VCC
3.6
0.7 VCC
0.75 VCC
V
0.7 VCC
0.7 VCC
VIL Maximum Low−Level
Input Voltage
2.0
0.25 VCC
0.25 VCC V
3.0
0.3 VCC
0.3 VCC
3.6
0.3 VCC
0.3 VCC
VOH High−Level Output
IOH = −50 mA
2.0
1.9
2.0
1.9
V
Voltage
IOH = −50 mA
3.0
2.9
3.0
2.9
IOH = −4 mA
3.0
2.58
2.48
VOL Low−Level Output
IOL = 50 mA
2.0
0.0
0.1
Voltage
IOL = 50 mA
3.0
0.0
0.1
IOL = 4 mA
3.0
0.36
0.1
V
0.1
0.44
IOZ Maximum 3−State
VIN = VIH or VIL
3.6
Leakage Current
VOUT = VCC or GND
±0.1
±1.0
mA
IIN Input Leakage Current
VIN = 5.5 V or GND
0 to 3.6
±0.1
±1.0
mA
ICC Maximum Quiescent
Supply Current
(per package)
VIN = VCC or GND
3.6
1.0
1.0
2.0
40
mA
AC ELECTRICAL CHARACTERISTICS Input tr = tf = 3.0 ns
ÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎ Symbol
ÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎ tPLH,
ÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎ tPHL
Parameter
Maximum Propagation
Delay, A or B to Y
ÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎ tPLH,
tPHL
Maximum Propagation
Delay, S to Y
ÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎ tPZL,
ÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎ tPZH
Maximum Output
Enable, Time, OE to Y
ÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎ tPLZ,
ÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎ tPHZ
Maximum Output
Disable, Time, OE to Y
ÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎ CIN MaximumInput
ÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎ Capacitance
Test Conditions
VCC = 2.7 V
CL = 15pF
CL = 50pF
VCC = 3.3 V ± 0.3 V
CL = 15pF
CL = 50pF
VCC = 2.7 V
CL = 15pF
CL = 50pF
VCC = 3.3 V ± 0.3 V
CL = 15pF
CL = 50pF
VCC = 2.7 V
RL = 1 kW
CL = 15pF
CL = 50pF
VCC = 3.3 V ± 0.3 V
RL = 1 kW
CL = 15pF
CL = 50pF
VCC = 2.7
RL = 1 kW
CL = 50pF
VCC = 3.3 V ± 0.3 V
RL = 1 kW
CL = 50pF
TA = 25°C
Min
Typ
Max
6.5
10.0
9.5
14.0
4.5
8.0
7.5
12.0
8.0
12.0
10.5 15.5
6.0
10.0
8.5
13.5
7.5
11.5
10.5 15.0
5.5
9.5
8.5
13.0
13.0 17.0
−40°C ≤ TA ≤ 85°C
Min
Max
Unit
1.0
15.0
ns
1.0
18.5
1.0
10.0
1.0
13.5
1.0
17.0
ns
1.0
20.0
1.0
12.0
1.0
15.5
1.0
16.5
ns
1.0
18.0
1.0
11.5
1.0
15.0
1.0
18.0
ns
12
17.0
1.0
18.0
4
10
10
pF
Typical @ 25°C, VCC = 3.3 V
CPD Power Dissipation Capacitance (Note 5)
20
pF
5. CPD is defined as the value of the internal equivalent capacitance which is calculated from the operating current consumption without load.
Average operating current can be obtained by the equation: ICC(OPR) = CPD VCC fin + ICC. CPD is used to determine the no−load dynamic
power consumption; PD = CPD VCC2 fin + ICC VCC.
http://onsemi.com
4