DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

MH32S72BBFA-6 데이터 시트보기 (PDF) - MITSUBISHI ELECTRIC

부품명
상세내역
제조사
MH32S72BBFA-6 Datasheet PDF : 56 Pages
First Prev 11 12 13 14 15 16 17 18 19 20 Next Last
MITSUBISHI LSIs
MH32S72BBFA -6
2,415,919,104-BIT ( 33,554,432-WORD BY 72-BIT ) Synchronous DYNAMIC RAM
FUNCTION TRUTH TABLE FOR CKE
Current State
CK
n-1
CK
n
SELF -
HX
REFRESH*1 L H
LH
LH
LH
LH
POWER
DOWN
L
L
HX
LH
L
L
ALL BANKS H H
IDLE*2
HL
HL
HL
HL
HL
HL
L
X
ANY STATE H H
other than
HL
listed above L
H
L
L
/S /RAS /CAS /WE Add
Action
X
X
X
X
X INVALID
H
X
X
X
X Exit Self-Refresh(Idle after tRC)
L
H
H
H
X Exit Self-Refresh(Idle after tRC)
L
H
H
L
X ILLEGAL
L
H
L
X
X ILLEGAL
L
L
X
X
X ILLEGAL
X
X
X
X
X NOP(Maintain Self-Refresh)
X
X
X
X
X INVALID
X
X
X
X
X Exit Power Down to Idle
X
X
X
X
X NOP(Maintain Self-Refresh)
X
X
X
X
X Refer to Function Truth Table
L
L
L
H
X Enter Self-Refresh
H
X
X
X
X Enter Power Down
L
H
H
H
X Enter Power Down
L
H
H
L
X ILLEGAL
L
H
L
X
X ILLEGAL
L
L
X
X
X ILLEGAL
X
X
X
X
X Refer to Current State = Power Down
X
X
X
X
X Refer to Function Truth Table
X
X
X
X
X Begin CK0 Suspend at Next Cycle*3
X
X
X
X
X Exit CK0 Suspend at Next Cycle*3
X
X
X
X
X Maintain CK0 Suspend
ABBREVIATIONS:
H = High Level, L = Low Level, X = Don't Care
NOTES:
1. CKE Low to High trans ition will re-enable CK and other inputs asynchronously.
A m inimum setup time must be satisfied before any command other than EXIT.
2. Power-Down and Self-Refresh can be entered only form the All banks idle State.
3. Must be legal command.
MIT-DS-333-0.1
MITSUBISHI
ELECTRIC
16/Jun. /1999 11

Share Link: 

datasheetq.com  [ Privacy Policy ]Request Datasheet ] [ Contact Us ]