NCP300, NCP301
5.0 V
Test Data
R1 = 100 kW
C (nF)
0.01
R2 = 82 kW
fOSC (kHz)
10.4
IQ (mA)
18
R2 = 8.2 kW
fOSC (kHz)
6.0
IQ (mA)
30
2 Input
0.068
9.8
18
5.7
30
R2 (See table)
1.0
6.18
21
3.6
29
C
NCP3010
1
HLSN27T1
Reset Output
10
1.41
100
0.27
21
1.34
25
22
0.356
23
3 GND
1000
0.045
22
0.077
22
Table values are for information only.
Figure 30. Simple Clock Oscillator
Rsense
Vsupply
Load
VDD
2 Input
NCP301
LSN2079T1
50 k
1
Reset Output
Microcontroller
3 GND
GND
This circuit monitors the current at the load. As
current flows through the load, a voltage drop with
respect to ground appears across Rsense where
Vsense = Iload * Rsense. The following conditions apply:
If:
ILoad t VDET − /Rsense
ILoad w (VDET −+VHYS)/Rsense
Then:
Reset Output = 0 V
Reset Output = VDD
Figure 31. Microcontroller System Load Sensing
http://onsemi.com