DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

M62399 데이터 시트보기 (PDF) - MITSUBISHI ELECTRIC

부품명
상세내역
제조사
M62399 Datasheet PDF : 5 Pages
1 2 3 4 5
MITSUBISHI<Dig.Ana.INTERFACE>
M62399P,FP
8-BIT 8CH I 2C-BUS D-A CONVERTER WITH BUFFER AMPLIFIERS
I2 C-BUS LINE CHARACTERISTICS
Symbol
fSCL
tBUF
tHD:STA
tLOW
tHIGH
tSU:STA
tHD:DAT
tSU:DAT
tR
tF
tSU:STO
Parameter
SCL clock frequency
Time the bus must be free before a new transmission can start
Hold time start condition.After this period.The first clock pulse is generated
The low period of the clock
The high period of the clock
Set up time for start condition(only relevant for a repeated start condition)
Hold time data
Set up time data
Rise time of both SDA and SCL lines
Fall time of both SDA and SCL lines
Set up time for stop condition
Normal mode High speed mode
Min Max Min Max
Unit
0 100
0
400 KHz
4.7
1.3
µs
4.0
0.6
µs
4.7
1.3
µs
4.0
0.6
µs
4.7
4.7
µs
0
0
0.9
µs
250
100
ns
1000 20 300
ns
300 20 300
ns
4.0
0.6
µs
*Note that transmitter must internally at reset a hold time to bridge the undefined region(max.300ns)of the falling edge of SCL.
TIMING CHART
VIL
SDA
VIH
tR, tF
VIL
SCL
VIH
tHD:STA
S
tSU:DAT
tHD:DAT
tLOW
tHIGH
tSU:STA
S
tBUF
tSU:STO
P
S
MITSUBISHI
ELECTRIC
( 4/5)

Share Link: 