Registers and descriptors description
ST802RT1A, ST802RT1B
Table 27. RN1C [0d28, 0x1C]: 10Base-T error and general status register
Bit Bit name
Description
Default
RW
Type
Type
15:14 RESERVED ---
00
RW
-
13
MDIX Status
1 -> MDI-X configuration used
0 -> MDI configuration used
0
RO
-
12
MDIX Swap
1 -> MDIX force (if not in fx_mode)
0 -> Normal operation
11
MDIX Disable
1 -> MDIX auto-detection and negotiation disabled
0 -> MDI-MDIX auto-detection enabled
0
RW
-
1
RW
-
10 RESERVED ---
0
1 -> Jabber condition detected
0 -> No jabber condition detected.
9 Jabber detect Set at jabber condition detection, cleared only after register read 0
(if no more jabber condition is present). Fixed to 0 in 100Base-X
modes. Same as RN01[1] and RN19[0]
RO P(LH)
RO LH
8
Polarity 1 -> Polarity changed event
Changed 0 -> No polarity changes
7:0 RESERVED ---
0
RO
-
001001
11b
RO
-
MDIX status: This bit indicates whether MDI or MDIX is in use.
MDIX swap: Setting this bit forces the device to MDIX. When this bit is 0, the MDIX status is
determined by auto-negotiation if auto-MDIX is enabled.
MDIX disable: Setting this bit disables auto-detection and negotiation of MDIX. Clearing this
bit enables auto-MDIX.
34/58
Doc ID 17049 Rev 1