Nexperia
74LV4066
Quad bilateral switches
7. Limiting values
Table 4. Limiting values
In accordance with the Absolute Maximum Rating System (IEC 60134). Voltages are referenced to GND (ground = 0 V).
Symbol Parameter
Conditions
Min Max Unit
VCC
supply voltage
IIK
input clamping current
IOK
output clamping current
ISW
switch current
Tstg
storage temperature
Ptot
total power dissipation
VI < 0.5 V or VI > VCC + 0.5 V
VO < 0.5 V or VO > VCC + 0.5 V
VO = 0.5 V to (VCC + 0.5 V)
Tamb = 40 C to +125 C
SO14 package
0.5
-
-
[1]
-
65
+7.0 V
20 mA
50 mA
25 mA
+150 C
[2]
-
500 mW
(T)SSOP14 package
[3]
400 mW
[1] The input and output voltage ratings may be exceeded if the input and output current ratings are observed.
[2] SO14 package: Ptot derates linearly with 8 mW/K above 70 C.
[3] (T)SSOP14 package: Ptot derates linearly with 5.5 mW/K above 60 C.
8. Recommended operating conditions
Table 5.
Symbol
VCC
VI
VO
Tamb
t/V
Recommended operating conditions
Parameter
Conditions
supply voltage
input voltage
output voltage
ambient temperature
in free air
input transition rise and fall rate VCC = 1.0 V to 2.0 V
VCC = 2.0 V to 2.7 V
VCC = 2.7 V to 3.6 V
VCC = 3.6 V to 5.5 V
Min
[1] 1.0
0
0
40
-
-
-
-
Typ
Max Unit
3.3
6V
-
VCC V
-
VCC V
-
+125 C
-
500 ns/V
-
200 ns/V
-
100 ns/V
-
50 ns/V
[1] The static characteristics are guaranteed from VCC = 1.2 V to VCC = 5.5 V, but LV devices are guaranteed to function down to VCC =
1.0 V (with input levels GND or VCC).
74LV4066
Product data sheet
All information provided in this document is subject to legal disclaimers.
Rev. 4 — 9 December 2015
© Nexperia B.V. 2017. All rights reserved
4 of 22