AC Characteristics (Ta = −40 to 85°C)
TC74LCX02F/FT/FK
Characteristics
Propagation delay time
Output to output skew
Symbol
Test Condition
tpLH Figure 1, Figure 2
tpHL
tosLH
tosHL
(Note)
VCC (V)
1.8±0.15
2.5±0.2
2.7
3.3 ± 0.3
2.7
3.3 ± 0.3
Min Max Unit
⎯ 20.0
⎯
7.0
ns
⎯
6.0
1.5 5.2
⎯
⎯
ns
⎯
1.0
Note: Parameter guaranteed by design.
(tosLH = |tpLHm − tpLHn|, tosHL = |tpHLm − tpHLn|)
Dynamic Switching Characteristics (Ta = 25°C, input: tr = tf = 2.5 ns, CL = 50 pF, RL = 500 Ω)
Characteristics
Symbol
Test Condition
Quiet output maximum dynamic VOL
Quiet output minimum dynamic VOL
VOLP VIH = 3.3 V, VIL = 0 V
|VOLV| VIH = 3.3 V, VIL = 0 V
Typ. Unit
VCC (V)
3.3
0.8
V
3.3
0.8
V
Capacitive Characteristics (Ta = 25°C)
Characteristics
Input capacitance
Output capacitance
Power dissipation capacitance
Symbol
CIN
COUT
CPD
fIN = 10 MHz
Test Condition
⎯
⎯
Typ. Unit
VCC (V)
3.3
7
pF
0
8
pF
(Note) 3.3
25
pF
Note:
CPD is defined as the value of the internal equivalent capacitance which is calculated from the operating
current consumption without load.
Average operating current can be obtained by the equation:
ICC (opr) = CPD・VCC・fIN + ICC /4 (per gate)
5