74LVC00A
Absolute Maximum Ratings (Note 4) (@TA = +25°C, unless otherwise specified.)
Symbol
Parameter
Rating
Unit
ESD HBM
Human Body Model ESD Protection
2
KV
ESD CDM
Charged Device Model ESD Protection
1
KV
ESD MM
Machine Model ESD Protection
200
V
VCC
Supply Voltage Range
VI
Input Voltage Range
-0.5 to 6.5
V
-0.5 to 6.5
V
VO
Voltage applied to output in high impedance or IOFF state
-0.5 to 6.5
V
VO
Voltage applied to output in high or low state
IIK
Input Clamp Current VI < 0
-0.3 to VCC +0.5
V
-50
mA
IOK
IO
ICC,, IGND
Output Clamp Current VO < 0
Continuous output current
Continuous current through Vcc or GND
-50
mA
±50
mA
±100
mA
TJ
Operating Junction Temperature
-40 to 150
°C
TSTG
PTOT
Storage Temperature
Total Power Dissipation
-65 to 150
°C
500
mW
Note:
4. Stresses beyond the absolute maximum may result in immediate failure or reduced reliability. These are stress values and device operation should
be within recommend values.
Recommended Operating Conditions (Note 5) (@TA = +25°C, unless otherwise specified.)
Symbol
Parameter
Conditions
VCC
Supply Voltage
VI
Input Voltage
VO
Output Voltage
Active Mode
VCC= 0V; Power Down Mode
Δt/ΔV
VCC = 1.65V to 2.7V
Input transition rise or fall rate
VCC = 2.7V to 3.6V
TA
Operating free-air temperature
Notes: 5. Unused inputs should be held at VCC or Ground.
Min
Max
1.65
5.5
0
5.5
0
VCC
0
5.5
20
10
-40
+125
Unit
V
V
V
V
ns/V
°C
74LVC00A
Document number: DS35257 Rev. 3 - 2
3 of 9
www.diodes.com
June 2012
© Diodes Incorporated