Force-Sense Switches
_________________________________Test Circuits/Timing Diagrams (continued)
V+ VL
VIN_ IN_ V+
VL
NO_ OR NC_
50Ω
MAX4554
MAX4555
MAX4556 COM_
EN
GND V-
V-
VOUT
CL
1000pF
V- IS CONNECTED TO GND (0V) FOR SINGLE-SUPPLY OPERATION.
Figure 13. Charge Injection
VL
VIN
0V
VOUT
∆VOUT
∆VOUT IS THE MEASURED VOLTAGE DUE TO CHARGE TRANSFER
ERROR Q WHEN THE CHANNEL TURNS OFF.
Q = ∆VOUT x CL
VL
ADDRESS
SELECT
V+ VL
V+ VL
MAX4554 NO_
MAX4555
MAX4556 NC_
IN_
COM_
EN GND V-
V-
1MHz
CAPACITANCE
ANALYZER
Figure 14. COM_, NO_, NC_ Capacitance
V+ 10nF
VL 10nF
V+
VL COM_
VIN
NETWORK
ANALYZER
OFF ISOLATION = 20 log
VOUT
VIN
50Ω
50Ω
VL
MAX4554
MAX4555
MAX4556
VOUT
MEAS.
REF
ADDRESS
IN_
NO_, NC_
SELECT
EN GND
V-
50Ω
50Ω
ON LOSS = 20 log
VOUT
VIN
CROSSTALK = 20 log
VOUT
VIN
10nF
V-
MEASUREMENTS ARE STANDARDIZED AGAINST SHORT AT SOCKET TERMINALS. OFF ISOLATION IS MEASURED BETWEEN COM_ AND "OFF" NO_ OR NC_ TERMINALS.
ON LOSS IS MEASURED BETWEEN COM_ AND "ON" NO_ OR NC_ TERMINALS. CROSSTALK IS MEASURED BETWEEN COM_ TERMINALS WITH ALL SWITCHES ON.
SIGNAL DIRECTION THROUGH SWITCH IS REVERSED; WORST VALUES ARE RECORDED. V- IS CONNECTED TO GND (0V) FOR SINGLE-SUPPLY OPERATION.
Figure 15. Frequency Response, Off-Isolation, and Crosstalk
26 ______________________________________________________________________________________