MITSUBISHI <INTELLIGENT POWER MODULES>
PM150CVA060
FLAT-BASE TYPE
INSULATED PACKAGE
THERMAL RESISTANCES
Symbol
Rth(j-c)Q
Rth(j-c)F
Rth(c-f)
Parameter
Junction to case Thermal
Resistances
Contact Thermal Resistance
Test Condition
Inverter IGBT part (per 1/6 module)
Inverter FWDi part (per 1/6 module)
Case to fin, Thermal grease applied (per 1 module)
Limits
Min.
Typ.
Max. Unit
—
—
0.308
—
—
0.47 °C/W
—
—
0.022
MECHANICAL RATINGS AND CHARACTERISTICS
Symbol
—
—
—
Parameter
Mounting torque
Mounting torque
Weight
Mounting part
Main terminal
Test Condition
Limits
Min.
Typ.
Unit
Max.
screw : M5
2.5
3.0
3.5 N • m
screw : M5
2.5
3.0
3.5 N • m
—
730
—
g
RECOMMENDED CONDITIONS FOR USE
Symbol
Parameter
Test Condition
Recommended value
Unit
VCC
Supply Voltage
Applied across P-N terminals
≤ 400
V
Applied between : VUP1-VUPC, VVP1-VVPC
VD
Control Supply Voltage
VWP1-VWPC, VN1-VNC
(Note-3)
15 ± 1.5
V
VCIN(ON)
VCIN(OFF)
tdead
Input ON Voltage
Input OFF Voltage
Arm Shoot-through
Blocking Time
Applied between : UP-VUPC, VP-VVPC, WP-VWPC
UN • VN • WN-VNC
For IPM’s each input signals
≤ 0.8
≥ 4.0
V
≥ 2.5
µs
fPWM
PWM Input Frequency
Using Application Circuit input signal of IPM, 3φ
Sinusoidal PWM VVVF inverter
≤ 20
kHz
(Note-3) With ripple satisfying the following conditions dv/dt swing ≤ ±5V/µs, Variation ≤ 2V peak to peak
Jun. 2005