ST2L01
ELECTRICAL CHARACTERISTICS OF OUTPUT 2 (VI=5V, IO2=10mA Tj = 0 to 125°C unless otherwise
specified. Typical values are referred at Tj = 25°C, CI = 1µF (Tantalum), CO1 = CO1 =1µF (X7R). Refer to
"Typical Application Circuit "figure with R1=R2=120Ω".
Symbol
Parameter
Test Conditions
Min. Typ. Max. Unit
VI
VO2
VREF
∆VO2
∆VO2
VD2
tTR
ISC2
IO2
IADJ
∆IADJ
SVR2
eN2
∆VREF
∆VREF
Operating Input Voltage
Output Voltage 2
Reference Voltage
(measured between pins 4
and 2)
Line Regulation 2
Load Regulation 2
Dropout Voltage 2
Transient Response
Current Limit 2
Minimum Load Current 2
Adjust Pin Current
Adjust Pin Current
Supply Voltage Rejection
Thermal Regulation 2
Output Noise 1
Temperature Stability
Long Term Stability
IO2 =5mA to 1A Tj = 0 to 125°C
Tj = 25°C
Tj = 25°C
IO1 = 5mA to 1A
Tj = 0 to 125°C
VI = 4.75 to 5.25V
VI = 4.75 to 5.25V
IO = 0.01 to 1A (Note 1)
IO = 1A
(Note 2)
Tj = 0 to 125°C
IO = 10 to 500mA trise = tfall = 1µs
(Note 3, 5)
RL = 0
Tj = 0 to 125°C
Tj = 0 to 125°C (Note 4)
Tj = 0 to 125°C
IO1 = 5mA to 1A
Tj = 0 to 125°C
VI = 4.75 to 5.25V
VI = 5 ±0.25V
IO1 = 100 mA
Tj = 0 to 125°C
(Note 5)
fI = 100Hz
fI = 1KHz
fI = 10KHz
fI = 100KHz
IO = 1A,
tPULSE = 30ms (Note 5)
B= 10Hz to 10KHz (Note 5)
Tj = 0 to 125°C (Note 5)
Tj = 125°C, 1000Hrs (Note 5)
4.5
V
2.45 2.5 2.55
V
1.225 1.25 1.275 V
1.2125 1.25 1.2875
0.004 0.2
%
0.08 0.4
%
1.1 1.3
V
<1
µs
1
A
1
mA
35
120
µA
0
5
µA
70
77
70
80
50
65
30
43
0.1
30
0.5
0.3
dB
%/W
µVrms
%VO
%VO
Note 1: Low duty cycle pulse testing with Kelvin connections are required in order to maintain accurate data
Note 2: Dropout Voltage is defined as the minimum differential voltage between VI and VO required to mantain regulation at VO. It is measured
when the output voltage drops 1% below its nominal value.
Note 3: Transient response is defined with a step change in load from 10mA to 500mA as the time from the load step until the output voltage
reaches it’s minimum value.
Note 4: Minimum load current is defined as the minimum current required at the output in order for the output voltage to maintain regulation.
Note 5: Guaranteed by design, not tested in production.
4/12