P2824
SPECIFICATIONS
Distortion
Exceed requirements of EN 50065-1 for conducted
emissions
Conditions:
Fundamental 132.45kHz into artificial mains network
of EN 50065-1 at 116dBµV and AC magnetizing
current of 3mA rms at 50Hz. Circuit as Figure 1.
Test Circuit
Fig 1
1µF
33nF
MAINS
Voltage Isolation
4kVrms at 50Hz
Operating range
Ambient
Storage
Relative Humidity
-25 to +85ºC
-40 to +125ºC
to 95%
Equivalent Circuit
Fig 2
Typical lumped parameters as Fig. 2, referred to pins 1-3.
Parameter
Series resistance RS
(DCR+ AC resistance)
Leakage inductance ΔL
Shunt inductance LP
Shunt loss RP
Conditions
125kHz, 1V
125kHz, 1V
125kHz, 1V
125kHz, 1V
Typical
1.3
46
1200
50
IDEAL
1:1
Units
Ω
µH
µH
kΩ
ETALDOC 438/10
Page 2 of 4