MP62160/MP62161 –CURRENT-LIMITED POWER DISTRIBUTION SWITCH
APPLICATION INFORMATION
Power-Supply Considerations
Over 10μF capacitor between IN and GND is
recommended. This precaution reduces power-
supply transients that may cause ringing on the
input and improves the immunity of the device to
short-circuit transients.
In order to achieve smaller output load transient
ripple, placing a high-value electrolytic capacitor
on the output pin(s) is recommended when the
load is heavy.
MP62160_MP62161 Rev. 0.9
www.MonolithicPower.com
9
7/8/2010
MPS Proprietary Information. Unauthorized Photocopy and Duplication Prohibited.