LT6658
Electrical Characteristics The l denotes the specifications which apply over the full operating temperature
range, otherwise specifications are at TA = 25°C. VIN = VIN1 = VIN2 = VOUT1,2_F + 2.5V, COUT1,2 = 1µF, ILOAD = 0, unless otherwise noted.
PARAMETER
CONDITIONS
MIN TYP MAX
UNITS
Ripple Rejection
Turn-On Time
Long Term Drift (Note 8)
VIN1 = VOUT1 + 3V, VRIPPLE = 0.5VP–P, fRIPPLE = 120Hz, ILOAD = 150mA,
COUT1 = 1µF, CNR = 10µF
VIN2 = VOUT2 + 3V, VRIPPLE = 0.5VP–P, fRIPPLE = 120Hz, ILOAD = 50mA,
COUT2 = 1µF, CNR = 10µF
0.1% Settling, CLOAD = 1μF
107
dB
107
dB
160
μs
120
ppm/√kHr
Thermal Hysteresis (Note 9) ∆T = –40°C to 85°C
∆T = –40°C to 125°C
30
ppm
45
ppm
Note 1: Stresses beyond those listed under Absolute Maximum Ratings
may cause permanent damage to the device. Exposure to any Absolute
Maximum Rating condition for extended periods may affect device
reliability and lifetime.
Note 2: Thermal hysteresis can occur during storage at extreme
temperatures.
Note 3: The stated temperature is typical for soldering of the leads during
manual rework. For detailed IR reflow recommendations, refer to the
Applications Information section.
Note 4: Temperature coefficient is measured by dividing the maximum
change in output voltage by the specified temperature range.
Note 5: Line and load regulation are measured on a pulse basis for
specified input voltage or load current ranges. Output changes due to die
temperature change must be taken into account separately.
Note 6: VOUT2 load regulation specification is limited by practical
automated test resolution. Please refer to the Typical Performance
Characteristics section for more information regarding actual typical
performance.
Note 7: Peak-to-peak noise is measured with a 1-pole highpass filter at
0.1Hz and 2-pole lowpass filter at 10Hz. The unit is enclosed in a still-air
environment to eliminate thermocouple effects on the leads. The test
time is 10 seconds. RMS noise is measured on a spectrum analyzer in
a shielded environment where the intrinsic noise of the instrument is
removed to determine the actual noise of the device.
Note 8: Long-term stability typically has a logarithmic characteristic
and therefore, changes after 1000 hours tend to be much smaller than
before that time. Total drift in the second thousand hours is normally less
than one third that of the first thousand hours with a continuing trend
toward reduced drift with time. Long-term stability will also be affected by
differential stresses between the IC and the board material created during
board assembly.
Note 9: Hysteresis in output voltage is created by package stress that
differs depending on whether the IC was previously at a higher or
lower temperature. Output voltage is always measured at 25°C, but
the IC is cycled to the hot or cold temperature limit before successive
measurements. Hysteresis measures the maximum output change for the
averages of three hot or cold temperature cycles. For instruments that
are stored at well controlled temperatures (within 20 or 30 degrees of
operational temperature), it’s usually not a dominant error source. Typical
hysteresis is the worst-case of 25°C to cold to 25°C or 25°C to hot to
25°C, preconditioned by one thermal cycle.
Note 10: The full current for ILOAD is 150mA and 50mA for Output 1 and
Output 2, respectively.