Rack & Cabinet Mount Switchers
C SERIES
50-12 kWatts
CE Marked - LVD & EMC
•
One to Four Outputs
•
5-400 Volts Output
•
Eurocassette or Wall Mount
•
Parallel Redundant Operation
•
Fully Wired Customised Racks
•
Power Factor Correction Modules
Specification
Input Voltage
•
Input Frequency
•
No-Load Input Current
•
Inrush Current
•
Switch-On Time
•
Hold-Up Time
•
High-Energy Pulses/Surges •
Spike/Bursts
•
Line Regulation (± 10%)
•
Load Regulation (10-90%) •
Ripple & Noise
•
Load Transient (20-100-20%) •
Response Time to ±1%
•
Overload Protection
•
Overvoltage Protection
•
Remote Sensing
•
Temperature Coefficient
•
Operating Temperature
•
Storage Temperature
•
Relative Humidity
•
Efficiency at Full Load
•
Switching Frequency
•
Isolation
•
RFI-Interference
•
M.T.B.F.
•
Construction (Safety)
•
Creepage Distance
•
Air Distance
•
Earth leakage
•
Connector
•
93-138 or 185-264 V AC (see Tables for 3 phase input)
47-440 Hz
3% of full load current typical
Limited by thermistor
100 ms typical C/M200-C4700, 500ms typical C5600-C5800
Increases with input voltage 15 ms typical at 230 V AC
ENV 50142 (level 3)
acc. to IEC 1000-4-4 (level 3)
0.1%
0.2%
≤ 1% + 30 mV p-p (0.5% typical lin.reg.aux.)
6% typical
2 ms typical C/M200-C4700, 10 ms typical C5600-C5800
Current limited at 105-110% of full load
Standard on single output models and main output on multi output units
OVP switches off module with automatic restart
Standard for main output
0.02%/°C typical
-20 °C to +75 °C derate from +55 ºC at 2.5%/ºC (Optional -40 ºC to +75 ºC)
-40 °C to +85 °C
5 to 95% Non condensing
60-95%, depending on model
approx. 33 kHz
Acc. to EN60950 class 1
Acc. to VDE 0878, EN 55022, level A
Approx. 250,000 hrs @ +25 °C
Acc. to EN 60950 class 1
Acc. to VDE 0110, 4 mm
Acc. to VDE 0110, 3 mm
<3.5 mA at 230 V AC, to EN60950
H 15 DIN 41612 or studs for higher current outputs C/M200-C4700, studs only
for C5600-C5800
Tel: +44 (0)118 984 5515 UK
Tel: +49 (0)700 9977 1000 D