IRSF3011
Absolute Maximum Ratings
Absolute maximum ratings indicate sustained limits beyond which damage to the device may occur.
(TC = 25oC unless otherwise specified.)
Symbol Parameter
Vds, max Continuous drain to source voltage
Vin, max Continuous input voltage
Ids
Continuous drain current
Pd
Power dissipation
EAS
Vesd1
Vesd2
TJop
TStg
TL
Unclamped single pulse inductive energyÁ
Electrostatic discharge voltage (Human Body Model)
Electrostatic discharge voltage (Machine Model)
Operating junction temperature range
Storage temperature range
Lead temperature (soldering, 10 seconds)
Min. Max. Units
—
50
V
-0.3
10
— self limited A
—
30
W
—
3
—
200
mJ
—
4000
V
—
1000
-55
150
-55
150
oC
—
300
Test Conditions
Tc £ 25oC, TO220
Tc £ 25oC, SOT223
100pF, 1.5kW
200pF, 0W
Static Electrical Characteristics
(TC = 25oC unless otherwise specified.)
Symbol Parameter
Vds,clamp Drain to source clamp voltage
Rds(on) Drain to source on resistance
Idss
Drain to source leakage current
Vth
Input threshold voltage
Ii,on
Input supply current (normal operation)
Ii, off
Input supply current (protection mode)
Vin, clamp Input clamp voltage
Vsd
Body-drain diode forward drop
Min.
50
—
—
—
—
—
—
—
1.5
—
—
—
—
10
—
Typ.
54
56
155
200
115
—
—
10
2.0
0.25
0.35
0.5
0.6
10.8
1.2
Max.
—
62
200
—
—
10
100
250
2.5
0.6
0.85
1.0
1.2
—
1.5
Units Test Conditions
V Ids = 10mA
Ids = 6A, tp = 700 ms
Vin = 5V, Ids = 2A
mW Vin = 4V, Ids = 2A
Vin = 10V, Ids = 2A
Vds = 12V, Vin = 0V
mA Vds = 50V, Vin = 0V
Vds=40V,Vin=0V,Tc=150oC
V Vds = 5V, Ids = 10mA
Vin = 5V
mA Vin = 10V
Vin = 5V
Vin = 10V
V Iin = 10mA
Ids = -9A, Rin = 1kW
Thermal Characteristics
Symbol Parameter
Rthjc
Rthja
Rthjc
Rthja
Junction to case
Junction to ambient
Junction to case
Junction to PCB
2
Min.
—
—
—
—
Typ.
—
—
—
—
Max. Units Test Conditions
4
TO-220AB
60
40
oC/W
SOT-223
60
www.irf.com