4.5.3. Return Loss:
4.5.3.1. Description:
The return loss of each filter under the specified conditions, either with or without the
ZHP-r attached, shall be greater than the value specified in page 6.
4.5.3.2. Test configuration:
Figure 3. defines the test configuration and the value of the test components that
shall be used for impedance measurement in the voice band for remote POTS filter.
Impedance of the load Z1=ZL & ZNL-r
Test
Equipment
Microfilter
POTS
Line
port
port
Z1
(load)
ZHP-r
(load)
Figure 3.
Note :
1. ZHP-r = the impedance presented to the POTS connection by an ATU-R.
2. ZL = real impedance 600 Ω.
3. ZNL-r = 1330 Ω in parallel with the series connection of a 348 Ω resistor and a
100nF capacitor.
4. Test apparatus: Impedance Analyzer HP 4284A or equivalent.