L6000
PULSE DETECTOR AND SERVO DEMODULATOR CHARACTERISTICS
Symbol
Parameter
Test Condition
Min.
Gain Sensititivity with respect to
27
DATA BYP or SERVO BYPS
pin voltage changes
AGC OUT/ THD
AGC OUT
AGCOUT - AGCOUT = 0.75Vpp 40
Differential Input Impedance
WG = low
4.7
Single Ended Input Impedance WG = low
2.5
WG = High or when IN Low - Z
mode
VOO
Output Offset Voltage
Filter not connected
– 200
en
Input Noise Voltage
AGC OUT, Rs = 0Ω, gain = 22
–
BW
Bandwidth
gain = 22 (1)
50
AGC OUT/ Single ended output resistance IO = 0
AGC OUT
PSRR Power Supply Rejection Ratio gain = 22, Fin = 5MHz
45
CMRR Common Mode Rejection Ratio
40
Gain Decay Time
AGC IN-AGC IN = 240mVpp to
–
120mVpp,
AGC OUT-AGC OUT = 0.9
Final Value
Gain Attack Time
AGC IN-AGC IN = 120mVpp to
–
240mVpp,
AGC OUT-AGC OUT = 1.1
Final Value
AGC Control Section
The input signal are AC coupled to DATA PATH and DATA PATH, C = 1000pF.
DATA PATH/ Signal Input range
(bench test only)
–
DATA PATH
Id
Discharge Current
2.8
Idf
Fast Discharge
During Fast Decay mode
Current
20xld
–30%
Ich
Charge Pump Attack Current DATA PATH-DATA PATH =
0.126
1.15Vpp
Ichf
Charge Pump Fast Attack
Current
DATA PATH-DATA PATH =
1.45V
7xlch
–30%
DATA BYP Pin Leakage Current WG = high
-0.1
LEVEL REF V Reference Voltage
Vcc
PULSE
DET-
2.47
LEVEL REF V Output Drive
Duration of shorted input and
Fast Decay modes
Level Output Gain
Level Output Bandwidth
Level Offset Voltage
-0.75
(*)
–
DATA PATH-DATA PATH = 0.5 0.60
to 1Vpp
fIN = 11MHz
–
Output - LEVEL REF V
–40
(IL = 40µA)
(*) Guaranted by design.
(1) For correlation automatic test is performed at –3.8dB.
(2) Test limits under evaluation.
Typ.
28
–
6
3.5
0.65
–
10
–
140
–
–
–
1
4
20xld
0.18
7xlch
–
–
1
0.67
–
–
Max.
Unit
dB/V
–
dB
8.4
KΩ
4.5
KΩ
0.8
KΩ
+200
15
–
180
mV
nV/√Hz
MHz
Ω
dB
–
dB
53
µs
2
µs
1.5 Vpp
5.2
µA
20xld µA
+30%
0.234 µA
7xlch µA
+30%
+0.1 µA
Vcc
V
PULSE
DET-
2.0
0.75 mA
–
µs
0.75 V/Vpp
2
dB (2)
+40 mV (2)
9/24