MB3829
RECOMMENDED OPERATING CONDITIONS(2)
Parameter
Symbol
Condition
Value
Unit
Min.
Typ.
Max.
Control input voltage
VI
0
Power
supply
control
section
Output current
Backup current
IO1 to IO3
- 50
IO4
- 10
IBATT1
CLR input pulse width
TCLR
200
OFF input pulse width
TOFF CT3 = 2.2 mF, RT3 = 1MW
10
ON2 input pulse width
TON2
10
ON setting
time setup
Capacitance
CT1
Resistance
RT1
Momentary
Capacitance
CT3
power - loss
time setup
Resistance
RT3
Speaker
amplifier
section
Control input voltage
Amplifier input voltage
Load resistance
VI
0
VIN
0.3
RL
8
Gain setting range
AV
When Non - INV input
6
VCC
V
mA
mA
200
mA
ns
ms
ms
1.5
mF
1
MW
2.2
mF
1
MW
VCC
V
VCC - 0.8
V
32
200
W
24
36
dB
When INV input
- 26
- 20
36
dB
Sounder
section
Control input voltage
Output current
Voltage
monitoring
section
RESET output current
Reset/hold time setup capacitance
Clock monitoring time setup
capacitance
Clock monitoring time setting
VI
IO1
IO2
IO3
IOL, IOH
CTP
CTW
TWD
Duty = 50%
Duty = 50%
Duty = 50%
0
VCC
V
200
mA
100
mA
50
mA
-3
3
mA
0.001
10
mF
0.001
1
mF
0.1
1500
ms
Note: The recommended operating conditions are the recommended values guaranteeing normal LSI operations. The specified