SERIAL DATA INPUTS
DATA NAME
FUNCTION
DATA = L DATA = H AT ACLX = L
D00-D06 SD0-SD6 Step of high speed shutter
–
All L
D07
SD7
D08
SD8
Number of exposed fields
–
All L
D09
SD9
D10
SMD
Electronic shutter mode control
–
L
D11
INMD Integration mode control
Monitoring
Still
L
D12
PWSA Power save control
Normal Power save
L
Polarity control of FCDS, FS and
D13
PLCH
Negative Positive
L
RS pulses
D14
DUMMY Dummy
–
–
D15
BCPCNT BCP control
Uncontinuously Continuously
L
D16
ML1
D17
ML2
L
–
L
D18
MR1
L
D19
MR2
–
L
D20
MR3
L
D21
MC1
L
D22
MC2
–
L
D23
MC3
L
Phase control
D24
MS1
L
D25
MS2
–
L
D26
MS3
L
D27
MF1
L
D28
MF2
–
L
D29
MF3
L
D30
MA1
D31
MA2
L
–
L
LR38616
7