CALIFORNIA MICRO DEVICES
WLP200
WLP200-01 FILTER CHARACTERISTICS (S21) MEASUREMENT (Continued)
NOTE: All the measurements are done with 50Ω-source & 50Ω-load impedance using a HP8753C Network Analyzer
with a HP85047A S-parameter Test Set.
S21 log MAG
1
5 dB/ REF 0 dB
2
1: –7.5079 dB
1.000 000 MHz
3
2: –10.504 dB
21.55 MHz
3: –19.2 dB
80 MHz
4: –41.775 dB
800 MHz
S21 log MAG
1
5 dB/ REF 0 dB
2
3
1: –4.6323 dB
1.000 000 MHz
2: –7.625 dB
34.1 MHz
3: –12.677 dB
80 MHz
4: –29.358 dB
4
800 MHz
4
START
.300 000 MHz
STOP 3 000.000 000 MHz
WLP200-01 Filter #5 D4-A4
START
.300 000 MHz
STOP 3 000.000 000 MHz
WLP200-01 Filter #6 D5-A5
WLP200-02 FILTER CHARACTERISTICS (S21) MEASUREMENT
NOTE: All the measurements are done with 50Ω-source & 50Ω-load impedance using a HP8753C Network Analyzer
with a HP85047A S-parameter Test Set.
S21 log MAG
1
5 dB/ REF 0 dB
S21 log MAG
1
5 dB/ REF 0 dB
2
3
1: –3.4364 dB
1.000 000 MHz
2: –6.44 dB
25.7 MHz
3: –13.557 dB
80 MHz
4: –31.79 dB
800 MHz
4
2
1: –5.8804 dB
1.000 000 MHz
3
2: –8.8746 dB
18 MHz
3: –18.985 dB
80 MHz
4: –40.299 dB
800 MHz
4
START
.300 000 MHz
STOP 3 000.000 000 MHz
WLP200-02 Filter #1 C1-B1
START
.300 000 MHz
STOP 3 000.000 000 MHz
WLP200-02 Filter #2 D1-A1
© 2000 California Micro Devices Corp. All rights reserved.
11/10/2000 215 Topaz Street, Milpitas, California 95035
Tel: (408) 263-3214
Fax: (408) 263-7846
www.calmicro.com
5