COMMAND TABLE
Bit Pattern
1010111X0
01X5X4X3X2X1X0
1011X3X2X1X0
0001X3X2X1X0
0000X3X2X1X0
1010000X0
1010011X0
1010010X0
1010001X0
11100000
11101110
11100010
1100X3 * * *
00101X2X1X0
00100X2X1X0
10000001
* * X5X4X3X2X1X0
1010110X0
* * * * * * X1X0
********
11100011
1111 * * * *
11110000
Write Command
(D/C=0, R/W(WR)=0, E(RD)=1)
Set Display On/Off
Set Display Start Line
Set Page Address
Set Higher Column Address
Set Lower Column Address
Set Segment Re-map
Set Normal/Reverse Display
Set Entire Display On/Off
Set LCD Bias
Set Read-Modify-Write Mode
Set End of Read-Modify-Write Mode
Software Reset
Set COM Output Scan Direction
Set Power Control Register
Set Internal Regulator Resistor Ratio
Set Contrast Control Register
Set Indicator On/Off
Comment
X0=0: turns off LCD panel (POR)
X0=1: turns on LCD panel
Set display RAM display start line register from 0-63 using
X5X4X3X2X1X0.
Display start line register is reset to 000000 during POR.
Set GDDRAM Page Address (0-8) using X3X2X1X0
Set the higher nibble of the colume address register using
X3X2X1X0 as data bits. The initial display line register is reset to
0000 during POR.
Set the lower nibble of the colume address register using
X3X2X1X0 as data bits. The initial display line register is reset to
0000 during POR.
X0=0: column address 00H is mapped to SEG0 (POR)
X0=1: column address 83H is mapped to SEG0
Refer to Fig. 5 for details.
X0=0: normal display (POR)
X0=1: reverse display
X0=0: normal display (POR)
X0=1: entire display on
X0=0: 1/8 bias (POR)
X0=1: 1/6 bias
For setting bias ratio to 1/4, 1/5, 1/7 or 1/9, see Extended Com-
mand Table.
Read-modify-write mode will be entered in which the column
address will not be incremented during display data read
Exit Read-modify-write mode. Column address before entering
the mode will be restored
Initialize the internal status
X3=0: normal mode (POR)
X3=1: remapped mode. COM0 to COM[N-1] becomes COM[N-1]
to COM0 in Multiplex ratio is equal to N. See Fig.5 as an
example for N equal to 56.
X0=0: turns off the output op-amp buffer (POR)
X0=1: turns on the output op-amp buffer
X1=0: turns off the internal regulator (POR)
X1=1: turns on the internal regulator
X2=0: turns off the internal voltage booster (POR)
X2=1: turns on the internal voltage booster
Internal regulator gain increases as X2X1X0 increased from 000b
to 111b. X2X1X0 = 100b (POR)
Set Contrast level from 64 contrast steps. Contrast increases as
X5X4X3X2X1X0 is increased.
X5X4X3X2X1X0 = 100000b (POR)
X0 = 0: indicator off (POR, no need of second command byte)
X0 = 1: indicator on (second command byte required)
Indicator Display Mode,
X1X0 = 00: indicator off
X1X0 = 01: indicator on and blinking at ~1 second interval
This second byte command is required X1X0 = 10: indicator on and blinking at ~1/2 second interval
ONLY when “Set Indicator On” com- X1X0 = 11: indicator on constantly
mand is sent.
Set Power Save Mode
Standby or sleep mode will be entered with compound commands
NOP
Command for No Operation
Set Test Mode
Reserved for IC testing. Do NOT use.
Test Mode Reset
Reserved for IC testing. Do NOT use.