LA76070
Parameter
Demodulation angle B-Y/R-Y
Demodulation angle B-Y/G-Y
Killer operating point
Chrominance VCO free-running
frequency
Chrominance pull-in range (+)
Chrominance pull-in range (–)
Auto flesh characteristic 73°
Auto flesh characteristic 118°
Auto flesh characteristic 163°
Symbol
ANGBR
ANGBG
KILL
CVCOF
PULIN +
PULIN –
AF073
AF118
AF163
Measurement
point
Input signal
30
C-1
28
29
C-1
30
C-3
15
CIN
No signal
30
C–1
30
C–1
30
C–4
28
30
C–4
28
30
C–4
28
Measurement procedure
Bus and other conditions
Measure the BOUT and ROUT output levels,
calculate the angles of the B-Y and R-Y axes,
and determine ANGBR as
<the R-Y angle> – <the B-Y angle>.
Measure the GOUT output level, calculate the
angle of the G-Y axis, and determine ANGBG
as <the G-Y angle> – <the B-Y angle>
Gradually lower the input signal level, and
measure the input signal level at the point the
output level falls under 150 mV p-p
Measure the oscillator frequency f, and
determine CVCOF from the following formula.
CVCOF = f – 3579545 (Hz)
Gradually lower the input signal subcarrier
frequency starting from 3.57545 MHz +
2000 Hz, and measure the frequency when
the output waveform locks
Gradually raise the input signal subcarrier
frequency starting from 3.57545 MHz –
2000 Hz, and measure the frequency when the
output waveform locks
With Auto Flesh = 0, measure the level that
corresponds to 73° for the BOUT and ROUT
output waveforms, and calculate the angle
AF073A.
With Auto Flesh = 1, determine the angle
AF073B in the same way.
Calculate AF073 from the following formula.
AF073 = AF073B – AF073A
TR22:
Auto flesh:
0*******
TR22:
Auto flesh:
1*******
With Auto Flesh = 0, measure the level that
corresponds to 118° for the BOUT and ROUT
output waveforms, and calculate the angle
AF118A.
With Auto Flesh = 1, determine the angle
AF118B in the same way.
Calculate AF118 from the following formula.
AF118 = AF118B – AF118A
TR22:
Auto flesh:
0*******
TR22:
Auto flesh:
1*******
With Auto Flesh = 0, measure the level that
corresponds to 163° for the BOUT and ROUT
output waveforms, and calculate the angle
AF163A.
With Auto Flesh = 1, determine the angle
AF163B in the same way.
Calculate AF163 from the following formula.
AF163 = AF163B – AF163A
TR22:
Auto flesh:
0*******
TR22:
Auto flesh:
1*******
No. 5844-17/27