Temperature Monitors and
PWM Fan Controllers
Register Summary (continued)
Addr(H)
02
03
06
08
READ/WRITE POR STATE
DESCRIPTION
Status register 1:
Bit 7: Local temp low:
1: Local temp low interrupt limit has been exceeded. This bit is cleared by
reading status register 1 for the MAX6653/MAX6663/MAX6664 or completing an
alert response protocol for the MAX6664. This bit is asserted on the next cycle if
the local temperature is still less than the limit.
Bit 6: Local temp high:
1: Local temp high interrupt limit has been exceeded. This bit is cleared by
reading status register 1 for the MAX6653/MAX6663/MAX6664 or completing an
alert response protocol for the MAX6664. This bit is asserted on the next cycle if
the local temperature is still greater than the limit.
Bit 5: Remote-diode error:
1: remote-diode short circuit or open circuit detected.
Bit 4: Remote temp THERM:
1: Remote temp THERM limit has been exceeded. This bit is cleared by reading
status register 1.
Bit 3: Remote temp low:
R
0000 0000
1: Remote temp low interrupt limit has been exceeded. This bit is cleared by
reading status register 1 for the MAX6653/MAX6663/MAX6664 or completing an
alert response protocol for the MAX6664. This bit is asserted on the next cycle if
the remote temperature is still less than the limit.
Bit 2: Remote temp high:
1: Remote temp high interrupt limit has been exceeded. This bit is cleared by
reading status register 1 for the MAX6653/MAX6663/ MAX6664 or completing an
alert response protocol for the MAX6664. This bit is asserted on the next cycle if
the remote temperature is still greater than the limit.
Bit 1: Fan fault:
1: The fan is running under speed. This bit is cleared by reading status register 1
or completing an alert response protocol. This bit is asserted again on the next
cycle if the fan fault still exists.
Bit 0: Alarm speed:
For MAX6663, this bit is set to 1 when the PWM duty cycle = 100%. Once read,
this bit does not reassert on the next monitoring cycle, even if the condition still
exists. It is asserted again if the condition is discontinued and then returns. For
the MAX6653/MAX6664, this bit is set to 1 when the THERM output goes to low.
Status register 2:
Bit 7: THERM:
1: THERM has been pulled low externally. This bit clears on a read of status
R
0000 0000
register 2.
Bit 6: Local temp THERM:
1: Local temp THERM limit has been exceeded. This bit is cleared by reading
status register 2.
Bits [5:0]: Unused.
Extended bits of temperature data:
R
0000 0000
Bits [7:5]: Extended bits for local temperature data.
Bits [4:3]: Unused.
Bits [2:0]: Extended bits for remote temperature data.
R
1111 1111
Fan-speed reading register:
This register contains the fan-speed tachometer measurement.