M29F016B
Table 10. DC Characteristics
(TA = 0 to 70°C, –40 to 85°C or –40 to 125°C)
Symbol
Parameter
Test Condit ion
Min
Max
Unit
ILI
Input Leakage Current
0V ≤ VIN ≤ VCC
±1
µA
ILO
Output Leakage Current
0V ≤ VOUT ≤ VCC
±1
µA
ICC1 Supply Current (Read)
E = VIL, G = VIH, f = 6MHz
20
mA
ICC2 Supply Current (Standby) TTL
E = VIH
2
mA
ICC3 Supply Current (Standby) CMOS
E = VCC ± 0.2V,
RP = VCC ±0.2V
800
µA
ICC4 (1) Supply Current (Program/Erase)
Program/Erase
Controller active
20
mA
VIL
Input Low Voltage
–0.5
0.8
V
VIH
Input High Voltage
2
VCC + 0.5
V
VOL Output Low Voltage
IOL = 5.8mA
0.45
V
Output High Voltage TTL
IOH = –2.5mA
2.4
V
VOH
Output High Voltage CMOS
IOH = –100µA
VCC – 0.4
V
VID
Identification Voltage
11.5
12.5
V
IID
Identification Current
A9 = VID
100
µA
VLKO (1)
Program/Erase Lockout Supply
Voltage
3.2
4.2
V
Note: 1. Sampled only, not 100% tested.
13/22