DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

LV4138W View Datasheet(PDF) - SANYO -> Panasonic

Part Name
Description
Manufacturer
LV4138W Datasheet PDF : 26 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
Continued from preceding page.
Parameter
Black limiter DC voltage
LV4138W
Symbol
VBLIM
Conditions
Input SIG5 (VL = 350mV) to (A) and adjust BLIM to
set the output of TP43 and TP40 to 9Vp-p.
Measure the DC voltage of TP40, TP43, and
TP45.
[Filter characteristics]
Parameter
TRAP attenuation amount
R-Y, B-Y LPF characteristics
Symbol
ATRAPN
ATRAPP
DEMLPF
Conditions
Input SIG2 (0dB, 3.58MHz and
NTSC
4.43MHz) in (A) and measure the TP43 PAL
output with a spectrum analyzer.
Assuming that the TP43 amplitude in
the TRAP ON mode is 0dB, determine
the attenuation in the COMP input
mode.
Input SIG5 (VL = 150mV) in (A) and SIG1
(100kHz) in (B). In this case, assume that the
amplitude of 100kHz component of TP40, TP45
output is 0dB. Change the SIG1 frequency at
which the output amplitude of TP40, TP45
becomes -3dB.
[Sync separation, TG system]
Parameter
Input sync signal width
sensitivity
Symbol
WSSEP
Sync separation input
sensitivity
VSSEP
Sync separation output delay
rate
TDSYL
TDSYH
Horizontal pull-in range
HPLLN
HPLLP
Conditions
Enter SIG5 (VL = 0mV, VS = 143mV, WS variable)
to (A) and confirm synchronization with the TP24
HD output. Narrow WS of SIG5 from 4.7μs and
determine WS at which synchronization between
the input and TP24HD output is lost.
Enter SIG5 (VL = 0mV, WS = 4.7μs, VS variable)
to (A) and confirm synchronization with the TP24
HD output. Reduce VS of SIG5 from 143mV and
determine VS at which synchronization between
the input and TP24HD output is lost.
(A) and measure the delay rate from TP6RPD
output. Assume that TDSYL is for a period from fall
of input HSYNC to fall of RPD output and that
TDSYH is for the period up to rise of RPD output.
Enter SIG5 (VL = 0mV, WS = 4.7μs, and
VS = 143mV, horizontal frequency
variable) to (A) and confirm
NTSC
PAL
synchronization with TP24 HD output.
Change the horizontal frequency of
SIG5 and determine the frequency fH at
which synchronization is established
from the condition in which input / output
synchronization is lost. Calculate as
follows : HPLLN = fH-15734
HPLLP = fH-15625
min
5.8
Ratings
typ
6.0
Ratings
min
typ
-15
-15
1.2
1.6
min
2.0
Ratings
typ
40
300
500
4.7
5.0
±500
±500
Unit
max
6.2
V
Unit
max
-20
dB
-20
dB
1.9 MHz
Unit
max
μs
60
mV
700
ns
5.3
μs
Hz
Hz
No.8926-6/26