MP03 XXX 130 Series
140
120
100
80
60
40
20
90˚
30˚
60˚
120˚
180˚
00
25
50
75
100
125
150
Mean on-state current - (A)
Fig. 7 Maximum permissible case temperature vs forward current per arm at various conduction angles, sine wave, 50/60Hz
140
120
100
80
60
40
20
30˚
60˚
90˚ 120˚
180˚ d.c.
00
25
50
75
100
125
150
Mean on-state current - (A)
Fig. 8 Maximum permissible case temperature vs forward current per arm at various conduction angles, square wave, 50/60Hz
7/10