ADN2870
SFP TIMING SPECIFICATIONS
Table 2.
Parameter
Symbol Min Typ
ALS Assert Time
t_off
1
ALS Negate Time1
t_on
0.83
Time to Initialize, Including t_init
25
Reset of FAIL1
FAIL Assert Time
t_fault
ALS to Reset time
t_reset
Max Unit Conditions/Comments
5
µs Time for the rising edge of ALS (TX_DISABLE) to when the bias
current falls below 10% of nominal.
0.95 ms Time for the falling edge of ALS to when the modulation current
rises above 90% of nominal.
275 ms From power-on or negation of FAIL using ALS.
100 µs
5
µs
Time to fault to FAIL on.
Time TX_DISABLE must be held high to reset TX_FAULT.
1 Guaranteed by design and characterization. Not production tested.
VSE
DATAP
DATAN
DATAP–DATAN
0V
V p-p DIFF = 2 × VSE
Figure 3. Signal Level Definition
SFP MODULE
VCC_Tx
1µH
0.1µF
0.1µF
3.3V
10µF
SFP HOST BOARD
Figure 4. Recommended SFP Supply
Rev. 0 | Page 5 of 20