PACKAGE CHARACTERISTICS
Table 2.
Parameter
Resistance (Input-to-Output)1
Capacitance (Input-to-Output)1
Input Capacitance
IC Junction-to-Ambient Thermal Resistance
IC Junction-to-Case Thermal Resistance
Moisture Sensitivity Level
Symbol
RI-O
CI-O
CI
θJA
θJC
Min Typ Max Unit Test Conditions
1012
Ω
2.0
pF
f = 1 MHz
4.0
pF
54
°C/W
13
°C/W
3
1 The device is considered a 2-terminal device: Pin 1 through Pin 14 are shorted together, and Pin 15 through Pin 28 are shorted together.
REGULATORY INFORMATION
The ADuM1420 will be approved by the organization listed in Table 3.
Table 3.
UL1 (Pending)
Recognized under 1577 component recognition program, basic insulation, 1667 V rms isolation voltage.
1 In accordance with UL 1577, each ADuM1420 is proof tested by applying an insulation test voltage ≥ 2000 V rms for 1 second (current leakage detection limit = 5 μA).
INSULATION AND SAFETY-RELATED SPECIFICATIONS
Table 4.
Parameter
Rated Dielectric Insulation Voltage
Minimum External Air Gap (Clearance)
Minimum External Tracking (Creepage)
Minimum Internal Gap (Internal Clearance)
Tracking Resistance (Comparative Tracking Index)
Isolation Group
Symbol
L(I01)
L(I02)
CTI
Value
1667
2.1 min
2.1 min
0.017 min
>175
IIIa
Unit
V rms
mm
mm
mm
V
Conditions
1-minute duration
Measured from input terminals to output terminals B-D,
shortest distance through air
Measured from input terminals to output terminals B-D,
shortest distance path along body
Insulation distance through insulation
DIN IEC 112/VDE 0303 Part 1
Material Group (DIN VDE 0110, 1/89, Table 1)
RECOMMENDED OPERATING CONDITIONS
Table 5.
Parameter
Operating Temperature
Input Supply Voltage1
Output Supply Voltages1
Input Signal Rise and Fall Times
Common-Mode Transient Immunity, Input to Output2
Common-Mode Transient Immunity, Between Outputs2
Transient Immunity, Supply Voltages2
1 All voltages are relative to their respective ground.
2 See the Common-Mode Transient Immunity section for additional data.
Symbol
TA
VDD1
VDDA, VDDB
Min
Max
−40
+105
4.5
5.5
12
18
100
−75
+75
−75
+75
−75
+75
Unit
°C
V
V
ns
kV/μs
kV/μs
kV/μs