PRELIMINARY
Table 5. Am29LV008B Command Definitions
Command
Sequence
(Note 1)
Read (Note 5)
1
Reset (Note 6)
1
Manufacturer ID
4
Auto- Device ID, Top Boot Block
4
select Device ID, Bottom Boot Block 4
(Note 7) Sector Protect Verify
(Note 8)
4
Program
4
Unlock Bypass
3
Unlock Bypass Program (Note 9)
2
Unlock Bypass Reset (Note 10)
2
Chip Erase
6
Sector Erase
6
Erase Suspend (Note 11)
1
Erase Resume (Note 12)
1
First
Addr Data
RA RD
XXX F0
555 AA
555 AA
555 AA
555 AA
555 AA
555 AA
XXX A0
XXX 90
555 AA
555 AA
XXX B0
XXX 30
Second
Addr Data
2AA 55
2AA 55
2AA 55
2AA 55
2AA 55
2AA 55
PA PD
XXX 00
2AA 55
2AA 55
Bus Cycles (Notes 2-4)
Third
Fourth
Addr Data Addr Data
555 90 X00 01
555 90 X01 3E
555 90 X01 37
555
90
(SA)
X02
00
01
555 A0 PA PD
555 20
555 80 555 AA
555 80 555 AA
Fifth
Sixth
Addr Data Addr Data
2AA 55 555 10
2AA 55 SA 30
Legend:
X = Don’t care
RA = Address of the memory location to be read.
RD = Data read from location RA during read operation.
PA = Address of the memory location to be programmed.
Addresses latch on the falling edge of the WE# or CE# pulse,
whichever happens later.
PD = Data to be programmed at location PA. Data latches on the
rising edge of WE# or CE# pulse, whichever happens first.
SA = Address of the sector to be verified (in autoselect mode) or
erased. Address bits A19–A13 uniquely select any sector.
Notes:
1. See Table 1 for description of bus operations.
2. All values are in hexadecimal.
3. Except when reading array or autoselect data, all bus cycles
are write operations.
4. Address bits A19–A11 are don’t cares for unlock and
command cycles.
5. No unlock or command cycles required when reading array
data.
6. The Reset command is required to return to reading array
data when device is in the autoselect mode, or if DQ5 goes
high (while the device is providing status data).
7. The fourth cycle of the autoselect command sequence is a
read cycle.
8. The data is 00h for an unprotected sector and 01h for a
protected sector. See “Autoselect Command Sequence” for
more information.
9. The Unlock Bypass command is required prior to the Unlock
Bypass Program command.
10. The Unlock Bypass Reset command is required to return to
reading array data when the device is in the unlock bypass
mode.
11. The system may read and program in non-erasing sectors, or
enter the autoselect mode, when in the Erase Suspend
mode. The Erase Suspend command is valid only during a
sector erase operation.
12. The Erase Resume command is valid only during the Erase
Suspend mode.
16