AMA28XXS Series
Dynamic Characteristics -55°C TCASE +125°C, VIN=28 VDC ±5%, CL=0, unless otherwise specified.
Parameter
Group A
Subgroups
Test Conditions
Min Nom Max Unit
Short Circuit Recovery 4
4, 5, 6 0% load to 100% load
25
ms
Switching Frequency
4, 5, 6 100% load
500 550
600
KHz
Output Response To Step
Transient Load Changes 8
4, 5, 6
Ù Load step 50% 100%
-450
4, 5, 6
Ù Load step 0% 50%
-750
+450
+750
mVpk
Recovery Time, Step Transient
Load Changes 5, 6
AMA2805S
AMA2812S
AMA2815S
AMA2805S
AMA2812S
AMA2815S
Output Response Transient Step
Line Changes 4, 7
AMA2805S
AMA2812S
AMA2815S
Recovery Time Transient Step
Line Changes 4, 6, 7
Turn On Overshoot 8
AMA2805S
4, 5, 6
4, 5, 6
4, 5, 6
4, 5, 6
4, 5, 6
4, 5, 6
Ù Load step 50% 100%
Ù Load step 0% 50%
4, 5, 6
4, 5, 6
4, 5, 6
4, 5, 6
Ù Input step 16 40Vdc,
100% load
Ù Input step 16 40Vdc,
100% load
4, 5
100% load
6
-550
-750
-750
300
100
100
µs
2000
2000
2000
+550
+750
+750
1200
mVpk
µs
600 mVpk
750
Turn On Overshoot 8
AMA2812S
AMA2815S
Turn On Delay 8
4, 5, 6 0 to 100% load
4, 5, 6 0% load to 100% load
600 mVpk
25
ms
Notes to Specifications
1. Parameter guaranteed by line and load regulation tests.
2. Bandwidth guaranteed by design. Tested for 20KHz to 2.0MHz.
3. Capacitive load may be any value from 0 to the maximum limit without compromising dc performance. A capacitive load in excess of
the maximum limit will not disturb loop stability but may interfere with the operation of the load fault detection circuitry, appearing
as a short circuit during turn on.
4. Parameter shall be tested as part of design characterization and after design or process changes. Parameters shall be guaranteed
to the limit specified in Electrical Specifications.
5. Load step transition time between 2 and 10 microseconds.
6. Recovery time is measured from the initiation of the transient to where VOUT has returned to within ±1 % of VOUT at 50 percent load.
7. Input step transition time between 2 and 10 microseconds.
8. Turn on delay time measurement is for either a step application of power at the input or the removal of a ground signal from the
inhibit pin while power is applied to the input.