DS2745 Low-Cost I2C Battery Monitor
CURRENT ACCUMULATION
The Accumulated Current register (ACR) serves as an up/down counter holding a running count of charge stored in
the battery. Current measurement results, plus a programmable bias value are internally summed, or accumulated,
at the completion of each current measurement conversion period with the results displayed in the ACR. The ACR
has a range of 0mVh to +409.6mVh with an LSb of 6.25μVhAdditional registers hold fractional results of each
accumulation, however, these bits are not user accessible. The ACR count clamps at FFFFh when accumulating
charge values and at 0000h when accumulating discharge values.
Read and write access is allowed to the ACR. Whenever the ACR is written, fractional accumulation results are
cleared. A write to the ACR also forces the ADC to measure its offset and update the offset correction factor.
Current measurement and accumulation resume (using the new offset correction) with the second conversion
following the write to the ACR. Figure 7 describes the ACR address, format, and resolution.
Figure 7. ACCUMULATED CURRENT REGISTER FORMAT
MSB—Address 10
LSB—Address 11
215 214 213 212 211 210 29 28
MSb
LSb
“S”: sign bit
27 26 25 24 23 22 21 20
MSb
LSb
Units: 6.25Vh/Rsns
Table 4. ACCUMULATED CURRENT RANGE FOR VARIOUS RSNS VALUES
VSS - VSNS
409.6mVh
20m
20.48Ah
ACR RANGE
RSNS
15m
27.31Ah
10m
40.96Ah
5m
81.92Ah
CURRENT OFFSET BIAS
The Current Offset Bias register (COBR) allows a programmable offset value to be added to raw current
measurements. The result of the raw current measurement plus the COBR value is displayed as the current
measurement result in the CURRENT register, and is used for current accumulation. The COBR value can be used
to correct for a static offset error, or can be used to intentionally skew the current results and therefore the current
accumulation.
Read and write access is allowed to COBR. Whenever the COBR is written, the new value is applied to all
subsequent current measurements. COBR can be programmed in 1.56V steps to any value between +198.1V
and -199.7V. The COBR value is stored as a two’s complement value in volatile memory, and must be initialized
via the interface on power-up. Figure 8 describes the COBR address, format, and resolution.
Figure 8. CURRENT OFFSET BIAS REGISTER FORMAT
Address 61
S 26 25
MSb
“S”: sign bit
24 23 22 21 20
LSb
Units: 1.56V/Rsns