PRELIMINARY - 6/15/93
AC Electrical Characteristics — Wait and Stop Timings (Continued)
Num
Characteristics
60MHz
Unit
Min
Max
30 DR Asserted to CLK low (Setup
Time for Synchronous Recovery
8
cyc+8 ns
from Wait State)
31 CLK low to DSO (ACK) Valid
(Enter Debug Mode) After Syn-
chronous Recovery from Wait
18cyc
—
ns
State
CLKO
(output)
DR
(input)
T0, T2 T1, T3
33
30
31
DSO
(output)
Wait and Stop 4.
Recovery from WAIT State Using DR Pin— Synchronous Timing
19
DSP56166 Technical Data Sheet
MOTOROLA