Signal/Connection Descriptions
Power
POWER
Power Name
VCCP
VCCQ
VCCA
VCCD
VCCS
Table 1-2 Power Inputs
Description
PLL Power—VCCP provides isolated power for the Phase Lock Loop (PLL). The
voltage should be well-regulated and the input should be provided with an
extremely low impedance path to the VCC power rail.
Quiet Power—VCCQ provides isolated power for the internal processing logic. This
input must be tied externally to all other chip power inputs. The user must provide
adequate external decoupling capacitors.
Address Bus Power—VCCA provides isolated power for sections of the address bus
I/O drivers. This input must be tied externally to all other chip power inputs. The
user must provide adequate external decoupling capacitors.
Data Bus Power—VCCD provides isolated power for sections of the data bus I/O
drivers. This input must be tied externally to all other chip power inputs. The user
must provide adequate external decoupling capacitors.
Serial Interface Power—VCCS provides isolated power for the SHI and SAI. This
input must be tied externally to all other chip power inputs. The user must provide
adequate external decoupling capacitors.
GROUND
Table 1-3 Grounds
Ground Name
GNDP
GNDQ
GNDA
GNDD
GNDS
Description
PLL Ground—GNDP is ground dedicated for PLL use. The connection should be
provided with an extremely low-impedance path to ground. VCCP should be
bypassed to GNDP by a 0.47 µF capacitor located as close as possible to the chip
package.
Quiet Ground—GNDQ provides isolated ground for the internal processing logic.
This connection must be tied externally to all other chip ground connections. The
user must provide adequate external decoupling capacitors.
Address Bus Ground—GNDA provides isolated ground for sections of the address
bus I/O drivers. This connection must be tied externally to all other chip ground
connections. The user must provide adequate external decoupling capacitors.
Data Bus Ground—GNDD provides isolated ground for sections of the data bus I/O
drivers. This connection must be tied externally to all other chip ground
connections. The user must provide adequate external decoupling capacitors.
Serial Interface Ground—GNDS provides isolated ground for the SHI and SAI. This
connection must be tied externally to all other chip ground connections. The user
must provide adequate external decoupling capacitors.