M27V401
Electronic Signature
The Electronic Signature (ES) mode allows the
reading out of a binary code from an EPROM that
will identify its manufacturer and type. This mode
is intended for use by programming equipment to
automatically match the device to be programmed
with its corresponding programming algorithm.
The ES mode is functional in the 25°C ± 5°C am-
bient temperature range that is required when pro-
gramming the M27V401. To activate the ES mode,
the programming equipment must force 11.5V to
12.5V on address line A9 of the M27V401, with
VPP = VCC = 5V. Two identifier bytes may then be
sequenced from the device outputs by toggling ad-
dress line A0 from VIL to VIH. All other address
lines must be held at VIL during Electronic Signa-
ture mode.
Byte 0 (A0 = VIL) represents the manufacturer
code and byte 1 (A0 = VIH) the device identifier
code. For the STMicroelectronics M27V401, these
two identifier bytes are given in Table 4 and can be
read-out on outputs Q7 to Q0. Note that the
M27V401 and M27C4001 have the same identifier
bytes.
ERASURE OPERATION (applies to UV EPROM)
The erasure characteristics of the M27V401 is
such that erasure begins when the cells are ex-
posed to light with wavelengths shorter than ap-
proximately 4000Å. It should be noted that sunlight
and some type of fluorescent lamps have wave-
lengths in the 3000-4000Å range. Research
shows that constant exposure to room level fluo-
rescent lighting could erase a typical M27V401 in
about 3 years, while it would take approximately 1
week to cause erasure when exposed to direct
sunlight. If the M27V401 is to be exposed to these
types of lighting conditions for extended periods of
time, it is suggested that opaque labels be put over
the M27V401 window to prevent unintentional era-
sure. The recommended erasure procedure for
the M27V401 is exposure to short wave ultraviolet
light which has a wavelength of 2537Å. The inte-
grated dose (i.e. UV intensity x exposure time) for
erasure should be a minimum of 15 W-sec/cm2.
The erasure time with this dosage is approximate-
ly 15 to 20 minutes using an ultraviolet lamp with
12000µW/cm2 power rating. The M27V401 should
be placed within 2.5 cm (1 inch) of the lamp tubes
during the erasure. Some lamps have a filter on
their tubes which should be removed before era-
sure.
9/15