ILX535K
Clock Pulse Recommended Timing
Item
Symbol Min.
Typ. Max. Unit
ฯROG, ฯ1 pulse timing
t1
50
100
โ
ns
ฯROG pulse high level period
t2
800
1000
โ
ns
ฯROG, ฯ1 pulse timing
t3
800
1000
โ
ns
ฯROG pulse rise time
t4
0
5
10
ns
ฯROG pulse fall time
t5
0
5
10
ns
ฯ1 pulse rise time/ฯ2 pulse fall time
t6
0
20
60
ns
ฯ1 pulse fall time/ฯ2 pulse rise time
ฯRS pulse high level period
ฯRS, ฯ1 pulse timing 1
t7
0
20
60
ns
t8
50
250โ1
โ
ns
t9
80
250โ1
โ
ns
ฯRS pulse rise time
t10
0
10
30
ns
ฯRS pulse fall time
t11
0
10
30
ns
Signal output delay time
ฯRS, ฯ1/ฯ2 pulse timing 2
t12
โ
70
โ
ns
t13
โ
10
โ
ns
t14
50
250โ1
โ
ns
โ1 These timing is the recommended condition under fฯRS = 1MHz.