Philips Semiconductors
ISP1102
Advanced USB transceiver
8. Electrostatic discharge (ESD)
8.1 ESD protection
For HBCC package, the pins that are connected to the USB connector (D+, D−,
VCC(5.0) and GND) have a minimum of ±12 kV ESD protection. The ±12 kV
measurement is limited by the test equipment. Capacitors of 4.7 µF connected from
Vreg(3.3) to GND and VCC(5.0) to GND are required to achieve this ±12 kV ESD
protection (see Figure 4).
The ISP1102W can withstand ±12 kV using the Human Body Model and ±5 kV using
the Contact Discharge Method as specified in IEC 61000-4-2.
RC
1 MΩ
charge current
limit resistor
RD
1500 Ω
discharge
resistance
HIGH VOLTAGE
DC SOURCE
CS
100 pF
storage
capacitor
DEVICE UNDER
TEST
A
VCC(5.0)
Vreg(3.3)
B
4.7 µF
4.7 µF
Fig 4. Human Body ESD test model.
GND
004aaa145
Note: For HVQFN package, the pins that are connected to the USB connector (D+,
D−, VCC(5.0) and GND) have a minimum of ±7 kV ESD protection.
8.2 ESD test conditions
A detailed report on test set-up and results is available on request.
9397 750 11228
Product data
Rev. 03 — 02 September 2003
© Koninklijke Philips Electronics N.V. 2003. All rights reserved.
8 of 23